Patient Monitor

Click to enlarge image

 Model Number PDJ-3000A

Specification:

ECG

Configuration: 5 lead

Lead input: 5 lead: RA, LA, RL, LL, V

Lead Selection: I,II, III, avR, avL, avF, V, MCL1

Gain: 4 grades optional

Sweep speed: 3 grades optional

Leakage of current: less than 3μA

Safety:endurance of voltage of 4000VAC/50Hz, defibrillation protection and contra electrotome interface

Indication for electrode cast: yes

Work mode: diagnosis, monitor, and surgery

Alarm indication: audible and visual, and can be reviewed

ST segment monitor: yes, and alarm range can be set.

Heart rate

Measuring range: 25 to 250 bpm

Accuracy: ±2 bmp

Tendency chart: 1~24 hours

Refurbishing rate: once for each beat

Alarm range: sustained adjustment of upper and lower limit between 20~250

Respiration

Measuring range: 1 ~ 99 bmp

Measuring error: ±2bmp

Measuring method: RA-LL Impedance

Display: waveform, respiratory rate

Alarm: yes

Alarm range: adjustable

Non-invasive pulse pressure

Measuring method: automatic vibration

Work mode: automatic/manual

Measuring parameters: SYST/DIAS/ MEAN/PR

Measuring mode: adult, pediatric, infant

Unit: mmHg or kPa

Excess pressure safety: double safe guard

Alarm range: 25 ~ 240 mmHg adjustable

SpO2

Measuring range: 0 ~100%

Accuracy: 80~100%:±2%, 60~79%:±3%, and have no requirements when less than 60%

Sensor type: double wavelength LBD

Resolution: ±1%

Alarm range: sustained adjustment of upper and lower limit between 1~100%

Alarm indication: audible and visual

Pulse rate monitor: yes

Pulse rate range: 0~255bmp

Temperature

Channel: two

Measuring range: 25~45oC

Unit: oC or  F

Accuracy: ±0.2oC

Alarm range: 25~45oC

Alarm indication: yes

Performance

Display: 12color TFT display to show 4 ~ 9 waveforms

Resolution: 640×480 or 800×600

Interface: interface for CRT display and net card

Tendency observation: tendency chart of 1 - 72 hours

Alarm: upper and lower limit alarm, audible and visual, third grade alarm

Connection: Can be connected to central monitor and long-distance monitor

Memory method: manual, alarm, timing, etc.

Built-in thermal printer